The Standard Specifications for the City of Monterey Park's Water System has been updated. This document lists the piping, valves, fire hydrants, service laterals and other equipment that are to be used for construction. Methods and controls for installation are also provided.
The document in its entirety can be downloaded here.
Specific drawings can be downloaded separately:
GENERAL DISTRIBUTION SYSTEM CONSTRUCTION
W-050 Standard Project Sign
W-060 Mandatory Flushing Sign
W-101 1 Inch Water Service Installation
W-102 2 Inch Water Service Installation
W-103 3/4 Inch through 2 Inch Double Check Backflow Prevention Assembly
W-104 3/4 Inch through 2 Inch Reduced Pressure Principle Backflow Prevention Assembly
W-105 Typical ¾ Inch through 2 Inch Domestic/Fire Protection Residential Backflow Installation
W-106 2 1/2" Temporary Water Service
W-110 Standard Fire Hydrant Installation
W-115 Water Facility Guard Posts
W-121 2" Blowoff Assembly (Non-Traffic Bearing)
W-122 2” Blowoff Assembly (Traffic Bearing)
W-124 4" Blowoff
W-126 Test Set Up for Newly Installed Improvements
W-130 Water and Sewer Separation Requirements
W-131 Water Minimum Separation from Other Utilities
W-132 Typical Casing Detail
W-138 Restraint of Joints for DIP and PVC at 90-Degree Vertical or Horizontal Bend
W-139 Restraint of Joints for DIP and PVC at a Dead End or Each Side of Valve
W-140 Typical Thrust Block Details (4" To 16" Dia. Fitting)
W-142 Thrust Block Area Requirements
W-143 Anchor Block Assembly for 6" Through 16" Pipe
W-144 Gravity Anchor Block Detail
W-150 Standard Valve Box Assembly
W-151 Valve Box and Stem Extension
W-152 Valve Box Raising
W-154 Water Main Connection at Intersections and Valve Markers
W-155 Valve Can Cover Code Chart
W-160 1" Air Release / Air-Vacuum / Combination-Air Valve Assembly
W-170 Water Main Offset/Siphon
W-180 Water Pipe Bedding Detail
LARGE SERVICES AND FIRE LINES
W-201 Large Meter and Fire Line Lateral Installation
W-203 Standard Meter Vault Installation
W-204 7-Inch x 14-Inch Hinged Reading Lid
W-205 Typical Manifold 4-10 Services
W-210 Pressure Regulating Vaults
W-220 Double Check Detector Assembly – Fire Line Only
W-221 Reduced Pressure Principle Detector Assembly – Fire Line Only
W-221A Reduced Pressure Principle Type Assembly for Large Services – Excluding Fire Lines
W-222 Compact Backflow Prevention Assembly – For Fire Line Only
W-222A Compact Backflow Prevention Assembly for Large Services – Excluding Fire Lines
W-229 Combination Meter and Backflow Prevention Device Above Ground Assembly
W-230 3 Inch, 4 Inch and 6 Inch Compound Meter Vault Assembly
W-230A 3 Inch, 4 Inch and 6 Inch Compound Meter Above Ground Assembly
W-250 3", 4" and 6" Irrigation Meter Vault Assembly
W-250A 3", 4" and 6" Irrigation Meter Above Ground Assembly
W-270 Adjustable Pipe Support
W-271 Adjustable Pipe Support w/ U-Bolt
MISCELLANEOUS DETAILS
W-601 Air Vent for U.G. Structures
W-605 Valve Installation on Existing Steel Pipe (CCP)
W-607 Water Sampling Station
W-608 Retaining Wall for Fire Hydrant and Other Water Appurtenances
W-609 Warning Identification Tape and Tracer Wire Installation for PVC and PVCO Pipe
W-610 Insulating Blanket
W-630 Destruction of Abandoned Water Wells